BIEN AIROTOR – PRESTIGE L

Out of Stock
Highlights:

Airotor handpiece

Description
  • Type –?Turbine with light, small head
  • Connection –?Using 4-way Unifix quick-connect coupling, rotating 360 degree
  • Speed of rotation –?335,000 rpm
  • Recommended air pressure –?3.1 bar
  • Cooling –?Diffuser, with 3 separate air and water sprays, water antiretraction valve
  • Chuck locking mechanism –?Push-button with anti-heating system
  • Light transmission –?Multi-strand optical glass conductor
  • Lighting –?Halogen
  • Cleaning/Sterilisation –?Thermo washer disinfectable / Steam autoclave up to 135 degree C
  • Weight –?73 g
  • Prestige L ref. –?1600380-001
  • Prestige L + 4-way Unifix set ref. –?1700184-001

 

MAINTENANCE OF TURBINES.

Preparation

A.REMOVING THE INSTRUMENT

  • Remove the rotary instrument from the chuck mechanism
Tissue_rubbing

B.PRE-DISINFECTION

  • External disinfection

Do not immerse the instrument in a disinfectant bath.

CLEANING

Cleaning_A

A.CLEAN UNDER RUNNING WATER AT <38?C

Cleaning_B

B.REMOVING DIRT/DEPOSITS

  • Carefully remove all traces of dirt or deposits from the spray nozzles using the Bien-Air cleaning wire
  • Dry the nozzles with compressed air then dry the rest of the instrument with a cloth

Do not immerse in an ultrasonic cleaner

Cleaning_CSpraynet-Tissue-spray_CTissue_rubbing_C

C.INTERNAL AND EXTERNAL CLEANING WITH SPRAYNET

  • Shake the?Spraynet?before use
  • Use the?Spraynet?attachment?1
    (for 2-/3-way and 4-way turbines, see inset below)
  • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the?Spraynet?button down for?1 second
  • Clean the exterior of the turbine with a cloth soaked in?Spraynet

FOR 2-/3-WAY AND 4-WAY TURBINES ONLY

Cleaning_C-primeBlack-Pearl-Eco_2-3waysBlack-Pearl-Eco_4-ways

C’.CLEANING THE INSIDE WITH SPRAYNET FOR 2-/3-WAY AND 4-WAY TURBINES ONLY

  • Use the?Spraynet?attachment?2
  • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the?Spraynet?button down for?1 second

Spray into the opening as shown in the illustrations for ?2-/3-way? and ?4-way?

DISINFECTION

Disinfectant-Tissue-spray_ATissue_rubbing_A

A.DISINFECTION USING SURFACE DISINFECTANT?(follow the manufacturer’s instructions for use)

Do not immerse the instrument in a disinfectant bath

OR

Thermal-disinfector

B.THERMAL DISINFECTION?(follow the manufacturer’s instructions for use)

LUBRICATION

Lubrification_A1Lubrification_A2

A.LUBRICATION WITH LUBRIMED

OR

Lubrification_B1Support_B

B.LUBRICATION WITH LUBRIFLUID

  • Shake the?Lubrifluid?before use
  • Use the?Lubrifluid?attachment?2,?3?ou?4depending on the type of instrument * (For 2-/3-way and 4-way turbines, see inset below)
  • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the?Lubrifluid?button down for?1 second
  • Then, run an operating test for 30 seconds at low speed to remove any surplus lubricant
  • Store immediately: store the instruments with the tip pointing downwards so that any oil residues can flow out

FOR 2-/3-WAY AND 4-WAY TURBINES ONLY

LubrificationBlack-Pearl-Eco_2-3waysBlack-Pearl-Eco_4-ways

B’.INTERNAL LUBRICATION WITH LUBRIFLUID FOR 2-/3-WAY AND 4-WAY TURBINES ONLY

  • Use the?Lubrifluid?attachment?2
  • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the?Lubrifluid?button down for?1 second

Spray into the opening as shown in the illustrations for ?2-/3-way? and ?4-way?

STERILISATION

Sterilization

A.PLACE THE TURBINE IN A STERILISATION BAG

Sterilizer

B.STERILISE IN ACCORDANCE WITH THE MANUFACTURER’S INSTRUCTIONS

  • Instruments bearing the “135?C” symbol can be sterilised in an autoclave

Only sterilise instruments which have been cleaned and lubricated